TY - JOUR
T1 - Clinical research on the accuracy in determining the pulse wave rising point
AU - Yambe, T.
AU - Shiraishi, Y.
AU - Saijo, Y.
AU - Liu, H.
AU - Nitta, S.
AU - Imachi, K.
AU - Baba, A.
AU - Yamaguchi, T.
AU - Sugawara, S.
AU - Katahira, Y.
AU - Ohsawa, N.
AU - Mibiki, Y.
AU - Watanabe, M.
AU - Shibata, M.
AU - Sato, N.
AU - Kameyama, T.
AU - Akino, N.
AU - Munakata, M.
AU - Honda, M.
AU - Yoshizawa, M.
AU - Sugita, N.
PY - 2009
Y1 - 2009
N2 - In the diagnosis and treatment of cardiovascular disease, various pulse wave parameters such as augmentation index in pulse wave measurement, baPWV, ABI, and CAVI are likely to be used more generally in the clinical setting. A critical point in pulse wave measurement is represented by accuracy. Determining the rising point of pulse waves, in particular, has considerable importance in ensuring diagnostic accuracy. Various methodologies for determining the rising point of pulse waves have been proposed. To compare each method, 1902 cases of measurement carried out in the clinical setting were reviewed. The pulse wave rising point was determined using the bottom method, the 1/10 method, the first derivative method, the second derivative method, the single tangent method, the intersecting tangents method, the McDonald method, and the amplitude adaptive tangent method. Detailed examination showed that the standard deviation was the smallest when the amplitude adaptive tangent method was used. Since the clinical setting does not always provide an ideal environment that allows accurate analytical measurement, it is critical to obtain stable measurement results. This research confirmed that the amplitude adaptive tangent method could be used to obtain measurement results exhibiting an accurate pulse wave rising point. In view of the possibility that future preventive medicine practices will expand into various facilities other than hospitals, as suggested by the efforts being made to fight metabolic syndrome, clinical research backed by practical footing will become increasingly important.
AB - In the diagnosis and treatment of cardiovascular disease, various pulse wave parameters such as augmentation index in pulse wave measurement, baPWV, ABI, and CAVI are likely to be used more generally in the clinical setting. A critical point in pulse wave measurement is represented by accuracy. Determining the rising point of pulse waves, in particular, has considerable importance in ensuring diagnostic accuracy. Various methodologies for determining the rising point of pulse waves have been proposed. To compare each method, 1902 cases of measurement carried out in the clinical setting were reviewed. The pulse wave rising point was determined using the bottom method, the 1/10 method, the first derivative method, the second derivative method, the single tangent method, the intersecting tangents method, the McDonald method, and the amplitude adaptive tangent method. Detailed examination showed that the standard deviation was the smallest when the amplitude adaptive tangent method was used. Since the clinical setting does not always provide an ideal environment that allows accurate analytical measurement, it is critical to obtain stable measurement results. This research confirmed that the amplitude adaptive tangent method could be used to obtain measurement results exhibiting an accurate pulse wave rising point. In view of the possibility that future preventive medicine practices will expand into various facilities other than hospitals, as suggested by the efforts being made to fight metabolic syndrome, clinical research backed by practical footing will become increasingly important.
KW - Amplitude adaptive tangent method
KW - Cardio ankle vascular index(CAVI)
KW - Pulse wave rising point
KW - Pulse wave velocity
UR - http://www.scopus.com/inward/record.url?scp=70350066425&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70350066425&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:70350066425
SN - 1211-3395
VL - 82
SP - 164
EP - 174
JO - Scripta Medica Facultatis Medicae Universitatis Brunensis Masarykianae
JF - Scripta Medica Facultatis Medicae Universitatis Brunensis Masarykianae
IS - 3
ER -