N2 - Some studies suggested a correlation between tissue elasticity and diseases, such as Adhesive Capsulitis (AC) of the shoulder. One category of method to measure elasticity is by utilizing Doppler imaging. This paper discusses color Doppler shear wave elastography methods and demonstrated an experiment with biological tissue mimicking phantom. A simulation with binary pattern color Doppler shear wave elastography shows that wavelength of a shear wave with suggested magnitude is equal to four multiple of pitch strip in a color flow image. However, the larger amplitude changes the duty ratio and frequency of the pattern. An experiment with biological tissue mimicking Polyvinyl Alcohol (PVA) phantoms has shown that the binary pattern color Doppler method has successfully recovered shear wave velocity map and calculate the elasticity.Clinical Relevance - The result of experiments presents a possibility of using the method for quantitatively access the stage of tissue stiffness related disease.
AB - Some studies suggested a correlation between tissue elasticity and diseases, such as Adhesive Capsulitis (AC) of the shoulder. One category of method to measure elasticity is by utilizing Doppler imaging. This paper discusses color Doppler shear wave elastography methods and demonstrated an experiment with biological tissue mimicking phantom. A simulation with binary pattern color Doppler shear wave elastography shows that wavelength of a shear wave with suggested magnitude is equal to four multiple of pitch strip in a color flow image. However, the larger amplitude changes the duty ratio and frequency of the pattern. An experiment with biological tissue mimicking Polyvinyl Alcohol (PVA) phantoms has shown that the binary pattern color Doppler method has successfully recovered shear wave velocity map and calculate the elasticity.Clinical Relevance - The result of experiments presents a possibility of using the method for quantitatively access the stage of tissue stiffness related disease.
UR - http://www.scopus.com/inward/record.url?scp=85122516059&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122516059&partnerID=8YFLogxK
U2 - 10.1109/EMBC46164.2021.9630967
DO - 10.1109/EMBC46164.2021.9630967
M3 - Conference contribution
C2 - 34891944
AN - SCOPUS:85122516059
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 3293
EP - 3296
BT - 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2021
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2021
Y2 - 1 November 2021 through 5 November 2021
ER -