Application of a NDI method using magneto-optical film for micro-cracks

Jaekyoo Lim, Hyoungno Lee, Jinyi Lee, Tetsuo Shoji

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Leakage magnetic flux is occurred in the cracked area of magnetized specimens, and also it changes the magnetic domain area of the magneto-optical film positioned on the specimen. It causes the change of the optical permeability of the magnetic domain on the crack area. So crack images can be obtained easily using this principle. On the other hand, utilizing a laser in this method makes possible to perform a remote sensing by detecting the light intensity contrast between cracked area and normal area. This paper shows the application of non-destructive inspection system taking advantage of magneto-optical method for micro-cracks and presents examples applied to the several types of specimens having fatigue cracks and fabricated cracks using this method. Also the authors prove the possibility of this method as a remote sensing system under the oscillation load considering application to real fields.

Original languageEnglish
Pages (from-to)591-598
Number of pages8
JournalKSME International Journal
Volume16
Issue number5
DOIs
Publication statusPublished - 2002 May

Keywords

  • Faraday Effect
  • Leakage Magnetic Flux (LMF)
  • Lift-off
  • MO Film (Magneto-Optical Film)
  • NDI (Non-Destructive Inspection)

ASJC Scopus subject areas

  • Mechanical Engineering

Fingerprint Dive into the research topics of 'Application of a NDI method using magneto-optical film for micro-cracks'. Together they form a unique fingerprint.

Cite this