Additional value of FDG PET/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms of the pancreas with mural nodules

Kentaro Takanami, Tomomichi Hiraide, Masashi Tsuda, Yasuhiro Nakamura, Tomohiro Kaneta, Kei Takase, Hiroshi Fukuda, Shoki Takahashi

Research output: Contribution to journalReview articlepeer-review

47 Citations (Scopus)

Abstract

Objectives: This study aimed at determining the additional value of FDG PET/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms (IPMNs) of the pancreas with mural nodules. Methods: This retrospective review of medical records was approved by our institutional review board. The preoperative PET/CT images of 16 non-diabetic patients with surgically proven IPMN, where mural nodules of 3 mm or larger were shown by preoperative contrast-enhanced CT, were retrospectively evaluated. The 16 patients were divided into two groups: 7 patients with benign IPMN [adenoma (n = 1) and borderline tumor (n = 6)] and 9 patients with malignant IPMN [carcinoma in situ (CIS) (n = 8) and invasive carcinoma (n = 1)]. Nuclear medicine physician blinded to the pathologic assessment of malignancy of IPMN set a spherical volume of interest (VOI) over the mural nodules on PET/CT images and recorded the peak standardized uptake value (SUV max) in the VOI, referring the contrast-enhanced CT images. Statistical differences in the size of mural nodule, the diameter of main pancreatic duct (MPD), and SUV max of the tumors between benign IPMNs and malignant IPMNs were compared using the Mann-Whitney U test. Statistical significance was set at p < 0.05. Additionally, the diagnostic accuracy of FDG PET for the detection of malignancy was calculated. Results: The SUV max of the malignant IPMNs with mural nodules of 3 mm or larger was higher than that of benign IPMNs (2.7 ± 0.6 vs. 1.9 ± 0.3, p < 0.01). Meanwhile, there was no significant difference in mural nodule diameter and MPD diameter between the two groups. FDG PET/CT showed an excellent diagnostic accuracy for the differentiation between malignant and benign IPMNs with mural nodules: the sensitivity, specificity, PPV, NPV, and accuracy in malignant IPMN with mural nodule of FDG PET/CT were 77.8, 100, 100, 77.8, and 87.5 for the cutoff value of 2.3; and 100, 57.1, 75.0, 100, and 81.3 for the cutoff value of 2.0, respectively. Conclusions: The result of this study indicates that FDG PET/CT can provide additional information for the differentiation between benign and malignant IPMNs of the pancreas with mural nodules.

Original languageEnglish
Pages (from-to)501-510
Number of pages10
JournalAnnals of Nuclear Medicine
Volume25
Issue number7
DOIs
Publication statusPublished - 2011 Aug

Keywords

  • CT
  • FDG
  • Intraductal papillary mucinous neoplasm of the pancreas
  • PET

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint Dive into the research topics of 'Additional value of FDG PET/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms of the pancreas with mural nodules'. Together they form a unique fingerprint.