Abstract
Using an oscilloscope as a differential amplifier, we built a simple and easily constructed system for wire-tension measurements by means of detecting the 3rd-harmonic signal of a mechanically vibrating wire, caused by an oscillating electric force.
Original language | English |
---|---|
Pages (from-to) | 2068-2069 |
Number of pages | 2 |
Journal | Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers |
Volume | 37 |
Issue number | 4 SUPPL. A |
DOIs | |
Publication status | Published - 1998 Apr |
Externally published | Yes |
Keywords
- BELLE
- Chamber
- Oscillating electric force
- RC circuit
- Third harmonic resonance oscillation
- Wire tension
ASJC Scopus subject areas
- Engineering(all)
- Physics and Astronomy(all)