T1 - A compact mid-infrared spectroscopy system for healthcare applications based on a wavelength-swept, pulsed quantum cascade laser
AU - Koyama, Takuya
AU - Shibata, Naoto
AU - Kino, Saiko
AU - Sugiyama, Atsushi
AU - Akikusa, Naota
AU - Matsuura, Yuji
N1 - Funding Information:
Funding: This research was funded by JSPS KAKENHI Grant Numbers JP17H03242 and JP18K18842.
Publisher Copyright:
© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2020/6/2
Y1 - 2020/6/2
N2 - A mid-infrared spectroscopic system using a high-speed wavelength-swept and pulsed quantum cascade laser (QCL) for healthcare applications such as blood glucose measurement is proposed. We developed an attenuated total reflection measurement system comprising the QCL with a micro-electromechanical system (MEMS)-scanning grating, hollow optical fibers, and InAsSb detector and tested its feasibility for healthcare applications. A continuous spectrum was obtained by integrating comb-shaped spectra, the timing of which was slightly shifted. As this method does not require complex calculations, absorption spectra are obtained in real-time. We found that the signal-to-noise ratio of the obtained spectrum had been improved by increasing the number of spectra that were integrated into the spectrum calculation. Accordingly, we succeeded in measuring the absorption spectrum of a 0.1% aqueous glucose solution. Furthermore, the absorption spectra of human lips were measured, and it was shown that estimation of blood glucose levels were possible using a model equation derived using a partial least squares regression analysis of the measured absorption spectra. The spectroscopic system based on the QCL with MEMS-scanning grating has the advantages of compactness and low cost over conventional Fourier transform infrared-based systems and common spectroscopic systems with a tunable QCL that has a relatively large, movable grating.
AB - A mid-infrared spectroscopic system using a high-speed wavelength-swept and pulsed quantum cascade laser (QCL) for healthcare applications such as blood glucose measurement is proposed. We developed an attenuated total reflection measurement system comprising the QCL with a micro-electromechanical system (MEMS)-scanning grating, hollow optical fibers, and InAsSb detector and tested its feasibility for healthcare applications. A continuous spectrum was obtained by integrating comb-shaped spectra, the timing of which was slightly shifted. As this method does not require complex calculations, absorption spectra are obtained in real-time. We found that the signal-to-noise ratio of the obtained spectrum had been improved by increasing the number of spectra that were integrated into the spectrum calculation. Accordingly, we succeeded in measuring the absorption spectrum of a 0.1% aqueous glucose solution. Furthermore, the absorption spectra of human lips were measured, and it was shown that estimation of blood glucose levels were possible using a model equation derived using a partial least squares regression analysis of the measured absorption spectra. The spectroscopic system based on the QCL with MEMS-scanning grating has the advantages of compactness and low cost over conventional Fourier transform infrared-based systems and common spectroscopic systems with a tunable QCL that has a relatively large, movable grating.
KW - ATR spectroscopy
KW - Hollow optical fiber
KW - Mid-infrared spectroscopy
KW - Quantum cascade laser
UR - http://www.scopus.com/inward/record.url?scp=85086638487&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85086638487&partnerID=8YFLogxK
U2 - 10.3390/s20123438
DO - 10.3390/s20123438
M3 - Letter
C2 - 32570744
AN - SCOPUS:85086638487
VL - 20
SP - 1
EP - 11
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
SN - 1424-8220
IS - 12
M1 - 3438
ER -